Clinic Sterilisation Room Setup: Dirty-to-Clean Workflow
An autoclave only sterilises what has been properly cleaned and packed. Here is how to lay out a clinic reprocessing area that works.
One-way flow: dirty to clean
Instruments should move in one direction — from the dirty zone, through cleaning and packing, to sterilising and clean storage — without crossing back.
1. Receiving and cleaning
A sink for soaking and manual cleaning, and ideally an ultrasonic cleaner or washer-disinfector. Wear gloves, apron and eye protection.
2. Inspection and packing
A clean, dry bench with a magnifier and good light. Check for residue and damage, lubricate handpieces, then pouch and label.
3. Sterilising
The autoclave, with space to load and unload, ventilation clearance and a nearby water supply for the reservoir.
4. Clean storage
Closed cupboards or drawers, off the floor and away from sinks, for dry pouched instruments.
Read next The four zones and the step-by-step workflow, with a room plan
Equipment checklist
- Deep sink with a separate hand-wash basin.
- Ultrasonic cleaner or washer-disinfector.
- Instrument brushes, detergent and personal protective equipment.
- Packing bench, pouches and a heat sealer if you use heat-seal pouches.
- Autoclave of the right class and size, with a water supply system.
- Indicator strips, Bowie-Dick or helix test and spore tests.
- Logbook or electronic record of every cycle and test.
Read next Instrument cleaning, step by stepChoosing an ultrasonic cleanerWasher-disinfectors explainedChoosing a pouch heat sealerStoring sterile instruments
Space and services
| Item | Plan for |
|---|---|
| Bench length | Separate dirty and clean sections, or two benches |
| Power | A dedicated socket for the autoclave; check its rating |
| Water | Distilled or deionised water supply, or a purifier unit |
| Ventilation | Clearance around the autoclave for heat and steam |
| Drainage | Required by some autoclave and washer models |
Read next Choosing autoclave feed waterPlanning a hospital CSSD
Related guides
Autoclave supply near you
Written quotes for clinics across Malaysia, handled from Batu Caves, Kota Kinabalu and Kuching.
Frequently asked questions
Do I need an ultrasonic cleaner before the autoclave?
Can the autoclave sit next to the sink?
How big should a clinic sterilisation area be?
Get a written quotation
Tell us your clinic or lab type, daily workload and location. We match suitable models and send a written quotation that states who handles delivery, installation and training, and what each costs.
010-905 2891 · Mon–Sat, 9:00 am – 6:00 pm