Spore Test Incubators and Biological Indicators: What to Buy for Your Autoclave
Weekly spore testing needs three things that must work together: the indicator, the incubator or reader, and the record. How the options differ, where brand lock-in hides, and how to compare the real cost per test.
What a spore-testing set-up is made of
This page is about choosing the kit. For how to place, run and read a spore test, see the method guide linked below.
Biological indicator (BI)
A known number of highly resistant spores on a carrier in a protective package. If the spores fail to grow after the cycle, the cycle was lethal enough. Steam BIs use Geobacillus stearothermophilus.
Control BI
An unprocessed indicator from the same lot, incubated alongside the test. It must grow, which proves the spores were alive and the medium and incubator work. CDC’s dental guidance calls for a matching control with each test.
Incubator or auto-reader
Holds the indicator at the temperature its instructions specify. A simple dry-block incubator is read by eye; an auto-reader detects growth itself and can store or send the result.
Activator and record
Most self-contained BIs are crushed or activated after the cycle to release their growth medium. The result belongs in your steriliser logbook with the lot number and the cycle it tested.
Read next How to run and read a spore test
Three ways to test
| Option | How it works | Suits | Watch for |
|---|---|---|---|
| Self-contained BI with an in-clinic incubator | You process the vial, activate it and incubate it; a colour change shows growth | Most clinics testing weekly in-house | The incubator must hold the temperature the BI’s instructions state; final read times vary by product, often a day or two |
| Rapid-readout BI with an auto-reader | The reader detects early signs of growth by fluorescence. Solventum’s Attest Auto-reader 490, for example, incubates its Attest steam BIs at 60 °C for a final result in 24 minutes, with software version 4.2.7 or later | Busy clinics and hospitals that want an answer the same session, including after a repair | The reader works only with its own brand’s indicators, and each test usually costs more |
| Spore strips sent to a laboratory | You process strips in your steriliser and post them; the laboratory transfers them to growth medium, incubates them and reports back | Low-volume users with no incubator | Days of delay before you know a cycle failed; check that a laboratory offering this service is available to you |
Choosing an incubator or reader
- Temperature: steam BIs are commonly incubated at about 55–60 °C, but the BI’s own instructions decide. Indicators for other processes, such as dry heat or ethylene oxide, use a different organism and a lower temperature.
- Compatibility: the BI’s instructions list the incubators or readers it has been validated with. Rapid readers only read their maker’s indicators.
- Wells: enough for the weekly test and control on every steriliser, plus repeat tests after a failure or repair.
- Read-out: colour change read by eye, or an automatic result with a printout, data export or network link. The Attest 490, for example, comes with an ethernet cable for connection to instrument-tracking systems.
- Temperature checks: a display or alarm, and a way to verify the block temperature with a calibrated thermometer.
- Power: ask for the Malaysian power supply and plug version. Manufacturer listings often show a US or European plug by default.
- Registration: in the United States, biological indicators are regulated as Class II medical devices. Ask your supplier for the MDA registration status of both the indicators and the reader.
Cost per test, and where lock-in hides
The incubator is a one-off. The indicators are the running cost, so price a year of testing, not the box.
- Buy quantities you will use before the indicators expire, and store them as the instructions say.
- With a rapid reader, you are committed to that brand’s indicators for the reader’s life. Ask how the indicators are supplied in Malaysia, the lead time, and whether the price is fixed for a period.
- Ask for the BI price including controls. A low per-vial price with a separate control pack can cost more in the end.
| Count this | Example: one steriliser tested weekly |
|---|---|
| Test indicators | 52 a year |
| Control indicators (one with each test) | 52 a year |
| Repeat tests after a positive result or a repair | Allow a few extra |
| Commissioning tests for a new or moved steriliser | As your validation plan sets |
| Reader or incubator: purchase, service and temperature verification | Once, then yearly |
How often to test, and what a positive means
- CDC recommends monitoring dental sterilisers at least weekly with a biological indicator and a matching control, and gives no separate schedule for part-time sterilisers.
- CDC’s dental guidelines also recommend a BI with every load that contains an implantable device, with the result checked before the implant is used whenever possible.
- Most policies add a BI after major repairs and at commissioning.
- After a positive test, CDC advises repeating the test straight away on the same cycle, and recalling and reprocessing items from loads back to the last negative test where possible.
Read next Retesting after a repairRecording results for traceability
Records that make the test worth doing
- Date, steriliser, cycle number and programme.
- BI brand, lot number and expiry date.
- Test result, control result, read time and who read it.
- The cycle printout or data record for the tested load.
- Action taken after any positive result, and the repeat-test result.
Read next Tape, pouches and chemical indicatorsChoosing a supplier
Related guides
Autoclave supply near you
Written quotes for clinics across Malaysia, handled from Batu Caves, Kota Kinabalu and Kuching.
Sources and further reading
- CDC — Guidelines for Infection Control in Dental Health-Care Settings, 2003 (MMWR 52, RR-17)
- CDC — Dental infection prevention FAQs: sterilization monitoring
- Solventum — Attest Auto-reader 490: 60 °C incubation and 24-minute steam BI results
- US eCFR — 21 CFR 880.2800, Sterilization process indicator (biological indicators are Class II devices)
- CDC — Guideline for Disinfection and Sterilization in Healthcare Facilities (2008, updated June 2024)
Frequently asked questions
Do I need an incubator for autoclave spore testing?
What temperature should a spore test incubator be?
Can I use any brand of biological indicator in my incubator?
How quickly do I get a spore test result?
What is in an autoclave spore test kit?
Can AA Alive quote a spore test incubator?
Get a written quotation
Tell us your clinic or lab type, daily workload and location. We match suitable models and send a written quotation that states who handles delivery, installation and training, and what each costs.
010-905 2891 · Mon–Sat, 9:00 am – 6:00 pm